Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.524
Filtrar
1.
Sci Rep ; 14(1): 8214, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589426

RESUMO

The feasibility of low frequency pure tone generation in the inner ear by laser-induced nonlinear optoacoustic effect at the round window was demonstrated in three human cadaveric temporal bones (TB) using an integral pulse density modulation (IPDM). Nanosecond laser pulses with a wavelength in the near-infrared (NIR) region were delivered to the round window niche by an optical fiber with two spherical lenses glued to the end and a viscous gel at the site of the laser focus. Using IPDM, acoustic tones with frequencies between 20 Hz and 1 kHz were generated in the inner ear. The sound pressures in scala tympani and vestibuli were recorded and the intracochlear pressure difference (ICPD) was used to calculate the equivalent sound pressure level (eq. dB SPL) as an equivalent for perceived loudness. The results demonstrate that the optoacoustic effect produced sound pressure levels ranging from 140 eq. dB SPL at low frequencies ≤ 200 Hz to 90 eq. dB SPL at 1 kHz. Therefore, the produced sound pressure level is potentially sufficient for patients requiring acoustic low frequency stimulation. Hence, the presented method offers a potentially viable solution in the future to provide the acoustic stimulus component in combined electro-acoustic stimulation with a cochlear implant.


Assuntos
Janela da Cóclea , Som , Humanos , Estimulação Acústica , Janela da Cóclea/fisiologia , Rampa do Tímpano/fisiologia , Lasers , Cóclea/fisiologia
2.
J Vis Exp ; (204)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38465931

RESUMO

Efficient and minimally invasive drug delivery to the inner ear is a significant challenge. The round window membrane (RWM), being one of the few entry points to the inner ear, has become a vital focus of investigation. However, due to the complexities of isolating the RWM, our understanding of its pharmacokinetics remains limited. The RWM comprises three distinct layers: the outer epithelium, the middle connective tissue layer, and the inner epithelial layer, each potentially possessing unique delivery properties. Current models for investigating transport across the RWM utilize in vivo animal models or ex vivo RWM models which rely on cell cultures or membrane fragments. Guinea pigs serve as a validated preclinical model for the investigation of drug pharmacokinetics within the inner ear and are an important animal model for the translational development of delivery vehicles to the cochlea. In this study, we describe an approach for explantation of a guinea pig RWM with surrounding cochlear bone for benchtop drug delivery experiments. This method allows for preservation of native RWM architecture and may provide a more realistic representation of barriers to transport than current benchtop models.


Assuntos
Orelha Interna , Janela da Cóclea , Cobaias , Animais , Janela da Cóclea/cirurgia , Orelha Interna/metabolismo , Cóclea , Sistemas de Liberação de Medicamentos , Modelos Animais
3.
J Int Adv Otol ; 20(1): 8-13, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38454282

RESUMO

BACKGROUND: This study proposed a classification of the vertical portion of the facial nerve (VPFN) location, incorporating the previous classifications regarding the posterior-to-anterior and medial-to-lateral dimensions. We also evaluated the implication of this proposed classification on the round window visibility during pediatric cochlear implantation (CI). METHODS: It was a retrospective multicenter observational cohort study. This study included 334 cases that underwent CI between 2015 and 2022 at multiple referral institutes. Two physicians evaluated the preoperative computed tomography images of 334 patients and determined the radiological type of the VPFN. These types were matched with intraoperative round window accessibility. RESULTS: The Spearman's correlation coefficient showed a strong correlation between the proposed VPFN type and the intraoperative round window visibility, as the P-value was <.001. CONCLUSION: This classification could provide the surgeon preoperatively with the precise location of the VPFN in the lateral-to-medial and posterior-to-anterior dimensions. Furthermore, this location classification of the VPFN was significantly correlated with intraoperative round window accessibility, with an accuracy of 90.42%. Therefore, types C and D were expected to have difficult accessibility into the round window, and more surgical interventions were needed to modify the posterior tympanotomy or use other approaches.


Assuntos
Implante Coclear , Humanos , Criança , Implante Coclear/métodos , Nervo Facial/diagnóstico por imagem , Nervo Facial/cirurgia , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia , Tomografia Computadorizada por Raios X/métodos , Janela da Cóclea/diagnóstico por imagem , Janela da Cóclea/cirurgia
4.
Otol Neurotol ; 45(4): e271-e280, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38346807

RESUMO

OBJECTIVES: The aim of this study is to improve our understanding of the mechanics involved in the insertion of lateral wall cochlear implant electrode arrays. DESIGN: A series of 30 insertion experiments were conducted by three experienced surgeons. The experiments were carried out in a previously validated artificial temporal bone model according to established soft surgery guidelines. The use of an in vitro setup enabled us to comprehensively evaluate relevant parameters, such as insertion force, intracochlear pressure, and exact electrode array position in a controlled and repeatable environment. RESULTS: Our findings reveal that strong intracochlear pressure transients are more frequently caused during the second half of the insertion, and that regrasping the electrode array is a significant factor in this phenomenon. For choosing an optimal insertion speed, we show that it is crucial to balance slow movement to limit intracochlear stress with short duration to limit tremor-induced pressure spikes, challenging the common assumption that a slower insertion is inherently better. Furthermore, we found that intracochlear stress is affected by the order of execution of postinsertion steps, namely sealing the round window and posterior tympanotomy with autologous tissue and routing of the excess cable into the mastoid cavity. Finally, surgeons' subjective estimates of physical parameters such as speed, smoothness, and resistance did not correlate with objectively assessed measures, highlighting that a thorough understanding of intracochlear mechanics is essential for an atraumatic implantation. CONCLUSION: The results presented in this article allow us to formulate evidence-based surgical recommendations that may ultimately help to improve surgical outcome and hearing preservation in cochlear implant patients.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Cóclea/cirurgia , Janela da Cóclea/cirurgia , Osso Temporal/cirurgia , Eletrodos Implantados
5.
J Assoc Res Otolaryngol ; 25(1): 35-51, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38278969

RESUMO

PURPOSE: Frequency selectivity is a fundamental property of the peripheral auditory system; however, the invasiveness of auditory nerve (AN) experiments limits its study in the human ear. Compound action potentials (CAPs) associated with forward masking have been suggested as an alternative to assess cochlear frequency selectivity. Previous methods relied on an empirical comparison of AN and CAP tuning curves in animal models, arguably not taking full advantage of the information contained in forward-masked CAP waveforms. METHODS: To improve the estimation of cochlear frequency selectivity based on the CAP, we introduce a convolution model to fit forward-masked CAP waveforms. The model generates masking patterns that, when convolved with a unitary response, can predict the masking of the CAP waveform induced by Gaussian noise maskers. Model parameters, including those characterizing frequency selectivity, are fine-tuned by minimizing waveform prediction errors across numerous masking conditions, yielding robust estimates. RESULTS: The method was applied to click-evoked CAPs at the round window of anesthetized chinchillas using notched-noise maskers with various notch widths and attenuations. The estimated quality factor Q10 as a function of center frequency is shown to closely match the average quality factor obtained from AN fiber tuning curves, without the need for an empirical correction factor. CONCLUSION: This study establishes a moderately invasive method for estimating cochlear frequency selectivity with potential applicability to other animal species or humans. Beyond the estimation of frequency selectivity, the proposed model proved to be remarkably accurate in fitting forward-masked CAP responses and could be extended to study more complex aspects of cochlear signal processing (e.g., compressive nonlinearities).


Assuntos
Cóclea , Nervo Coclear , Animais , Humanos , Potenciais de Ação , Janela da Cóclea , Chinchila
6.
Hear Res ; 442: 108950, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38218017

RESUMO

Countless therapeutic antibodies are currently available for the treatment of a broad range of diseases. Some target molecules of therapeutic antibodies are involved in the pathogenesis of sensorineural hearing loss (SNHL), suggesting that SNHL may be a novel target for monoclonal antibody (mAb) therapy. When considering mAb therapy for SNHL, understanding of the pharmacokinetics of mAbs after local application into the middle ear is crucial. To reveal the fundamental characteristics of mAb pharmacokinetics following local application into the middle ear of guinea pigs, we performed pharmacokinetic analyses of mouse monoclonal antibodies to FLAG-tag (FLAG-mAbs), which have no specific binding sites in the middle and inner ear. FLAG-mAbs were rapidly transferred from the middle ear to the cochlear fluid, indicating high permeability of the round window membrane to mAbs. FLAG-mAbs were eliminated from the cochlear fluid 3 h after application, similar to small molecules. Whole-body autoradiography and quantitative assessments of cerebrospinal fluid and serum demonstrated that the biodistribution of FLAG-mAbs was limited to the middle and inner ear. Altogether, the pharmacokinetics of mAbs are similar to those of small molecules when locally applied into the middle ear, suggesting the necessity of drug delivery systems for appropriate mAb delivery to the cochlear fluid after local application into the middle ear.


Assuntos
Orelha Interna , Perda Auditiva Neurossensorial , Camundongos , Cobaias , Animais , Anticorpos Monoclonais/metabolismo , Distribuição Tecidual , Orelha Interna/metabolismo , Cóclea/metabolismo , Orelha Média , Janela da Cóclea/metabolismo , Perda Auditiva Neurossensorial/metabolismo
7.
J Laryngol Otol ; 138(2): 142-147, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37246511

RESUMO

OBJECTIVES: To describe how the retrotympanic structures could influence the visibility of the round window niche and the round window membrane during cochlear implant surgery, and to investigate if a round window approach is possible even in cases with unfavourable anatomy. METHODS: Video recordings from 37 patients who underwent cochlear implantation were reviewed. The visibility of the round window niche and round window membrane at different timepoints was assessed according to a modified version of the Saint Thomas Hospital classification. The structures that concealed the round window niche and round window membrane were evaluated. RESULTS: After posterior tympanotomy, 54 per cent of cases had limited exposure (classes IIa, IIb and III) of the round window niche. After remodelling the retrotympanum, round window niche visibility significantly increased, with 100 per cent class I and IIa cases. Following remodelling of the round window niche, visibility of more than 50 per cent of the round window membrane surface was achieved in 100 per cent of cases. CONCLUSION: Remodelling the retrotympanum and the round window niche significantly increased exposure of the round window niche and round window membrane respectively, allowing round window insertion in all cases.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Janela da Cóclea/cirurgia , Janela da Cóclea/anatomia & histologia , Ventilação da Orelha Média , Gravação em Vídeo
8.
Laryngoscope ; 134(3): 1396-1402, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37638702

RESUMO

OBJECTIVES: To determine the morphologies and effect of the round window niche veil (RWNV) on local drug delivery efficacy and develop diagnostic criteria on high-resolution computed tomography (HRCT). METHODS: Patients diagnosed with otosclerosis, bilateral profound sensorineural hearing loss or vestibular schwannoma were enrolled from 2019 to 2022, receiving temporal bone HRCT scanning, and anatomic variations of RWMV were summarized intraoperative. For patients with vestibular schwannoma, 1 mL of dexamethasone solution (4 mg/mL) was administered via facial recess during operation, and samples of perilymph were collected to analyze. The diagnostic criteria of RWNV on HRCT were developed and verified. RESULTS: A total of 85 patients were enrolled. RWNV was observed in 54 cases intraoperatively with an incidence of 63.5% (95% CI, 52.9%-73.0%). The median perilymph concentrations were 4.86-fold higher in the group without RWNV than with RWNV (p < 0.0001). RWNV could be visualized on HRCT with a window width of 3500-4500 HU and a window level of 300-500 HU. The characteristic features were as follows: (1) a thin soft tissue shadow could be seen at the entrance of the round window niche (RWN); (2) it was visible in at least 2 consecutive layers along the upper margin of RWN from top to bottom; (3) it was discontinuous with the adjacent bone margin. The sensitivity and specificity of the diagnostic criteria were 77.8% and 93.6%, respectively. CONCLUSION: RWNV could reduce local dexamethasone diffusion efficacy to the inner ear, which could be diagnosed on HRCT and used as a predictor of local drug delivery efficacy to the inner ear. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:1396-1402, 2024.


Assuntos
Orelha Interna , Perda Auditiva Neurossensorial , Neuroma Acústico , Humanos , Janela da Cóclea/diagnóstico por imagem , Janela da Cóclea/cirurgia , Orelha Interna/diagnóstico por imagem , Perda Auditiva Neurossensorial/diagnóstico por imagem , Perda Auditiva Neurossensorial/cirurgia , Tomografia Computadorizada por Raios X/métodos , Dexametasona/uso terapêutico
9.
Laryngoscope ; 134(2): 945-953, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37493203

RESUMO

OBJECTIVES: Current surgical techniques aim to preserve intracochlear structures during cochlear implant (CI) insertion to maintain residual cochlear function. The optimal technique to minimize damage, however, is still under debate. The aim of this study is to histologically compare insertional trauma and intracochlear tissue formation in humans with a CI implanted via different insertion techniques. METHODS: One recent temporal bone from a donor who underwent implantation of a full-length CI (576°) via round window (RW) insertion was compared with nine cases implanted via cochleostomy (CO) or extended round window (ERW) approach. Insertional trauma was assessed on H&E-stained histological sections. 3D reconstructions were generated and virtually re-sectioned to measure intracochlear volumes of fibrosis and neo-ossification. RESULTS: The RW insertion case showed electrode translocation via the spiral ligament. 2/9 CO/ERW cases showed no insertional trauma. The total volume of the cochlea occupied by fibro-osseous tissue was 10.8% in the RW case compared with a mean of 30.6% (range 8.7%-44.8%, N = 9) in the CO/ERW cases. The difference in tissue formation in the basal 5 mm of scala tympani, however, was even more pronounced when the RW case (12.3%) was compared with the cases with a CO/ERW approach (mean of 93.8%, range 81% to 100%, N = 9). CONCLUSIONS: Full-length CI insertions via the RW can be minimally traumatic at the cochlear base without inducing extensive fibro-osseous tissue formation locally. The current study further supports the hypothesis that drilling of the cochleostomy with damage to the endosteum incites a local tissue reaction. LEVEL OF EVIDENCE: 4: Case-control study Laryngoscope, 134:945-953, 2024.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Estudos de Casos e Controles , Cóclea/cirurgia , Janela da Cóclea/cirurgia , Osso Temporal/cirurgia , Eletrodos Implantados
10.
Biomech Model Mechanobiol ; 23(1): 87-101, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37548872

RESUMO

Due to ethical issues and the very fine and complex structure of the cochlea, it is difficult to directly perform experimental measurement on the human cochlea. Therefore, the finite element method has become an effective and replaceable new research means. Accurate numerical analysis on human ear using finite element method can provide better understanding of sound transmission and can be used to assess the influence of diseases on hearing and to treat hearing loss. In this research, a three-dimensional (3D) finite element model (FEM) of the human ear of cochlea was presented to investigate the destruction of basilar membrane (BM), round window (RW) sclerosis and perilymph fistula, the key structures of the cochlea, and analyze the effects of these abnormal pathological states in the cochlea on cochlear hearing, resulting in the changes in cochlear sense structure biomechanical behavior and quantitative prediction of the degree and harm of the disorder to the decline of human hearing. Therefore, this paper can deepen reader's understanding of the cochlear biomechanical mechanism and provide a theoretical foundation for clinical otology.


Assuntos
Cóclea , Perda Auditiva , Humanos , Audição , Janela da Cóclea , Membrana Basilar
11.
Am J Otolaryngol ; 45(1): 104050, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37741025

RESUMO

BACKGROUND: Cochlear implantation (CI) in children with malformed ears can be challenging through the standard surgical technique. Several alternative approaches have been described. The endoscopic-assisted approach can be chosen as an effective and safe surgical technique, overcoming the drawbacks of the traditional approach. MATERIAL: We further describe a combined technique based on a limited mastoidectomy with no posterior tympanotomy and an endoscopic transmeatal approach to the round window (RW): the electrode is driven from the mastoid to the middle ear through the attic. RESULTS: The concomitant endoscopic assistance allows for improved surgical vision, reducing the risk of major complications. The main advantages of this technique are related to better visualization of the RW for safe insertion of the electrode; avoidance of damage to the facial nerve (FN), due to direct visualization, and sparing the posterior tympanotomy; avoidance of subtotal petrosectomy, if not necessary. CONCLUSION: The purpose of this article, supported with a video file, is to describe step by step this endoscopic-assisted procedure in a patient with middle ear malformation.


Assuntos
Implante Coclear , Implantes Cocleares , Criança , Humanos , Implante Coclear/métodos , Orelha/cirurgia , Orelha Média/cirurgia , Audição , Janela da Cóclea/cirurgia
13.
Cir Cir ; 91(6): 824-828, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38096868

RESUMO

OBJECTIVE: Determine the effectiveness of endoscopy in cochlear implantation as compared to microscopy. METHOD: Study comparing microscopy and endoscopy in cochlear implant placement in 34 patients (23 endoscopic implants and 20 implants via microscopy), between 2014 and 2019, at the Centro Medico Naval, Mexico City. The study was performed under informed consent and according to the Council for International Organizations of Medical Sciences (CIOMS). RESULTS: Of the 34 patients, 12 were children or adolescents and 22 were adults. The visualization of the round window classified via microscopy per St. Thomas Hospital's classification showed that type IIB prevailed in 30.2% of patients, and type III in 41.9%, and when using the endoscope, the round window was observed in full in 82.6% of patients (type I), and type IIA was only observed in 17.4% (four patients). The number of attempts made to place the cochlear implant was greater with the microscope. The time to insertion of the electrode was 1.6 minutes. No differences were observed (p > 0.05) in the number of inpatient days. Cochleostomy was more frequent when using the microscope. CONCLUSIONS: Endoscopy is an effective resource in cochlear implantation for posterior tympanotomy, with no complications observed, offering greater safety in inserting the electrode through the round window.


OBJETIVO: Determinar la efectividad de la endoscopía en la implantación coclear en comparación con la técnica microscópica. MÉTODO: Se comparó la microscopía frente a la endoscopía en la colocación de implante coclear en 34 pacientes (23 endoscópicos y 20 microscópicos), del año 2014 al año 2019, en el Centro Médico Naval de la Ciudad de México. El estudio se realizó bajo consentimiento informado y apegado a las normas del Council for International Organizations of Medical Sciences. RESULTADOS: De los 34 pacientes, 12 eran niños o adolescentes y 22 eran adultos. La visualización de la ventana redonda fue clasificada con microscopio según la clasificación del St. Thomas Hospital, predominando la tipo IIB (30.2%) y la III (41.9%), y al utilizar el endoscopio se observó completa en el 82.6% (tipo I) y tipo IIA en tan solo el 17.4% (cuatro pacientes). El número de intentos en la colocación del implante coclear fue mayor con el microscopio. El tiempo en el que se insertó el electrodo fue de 1.6 minutos. No hubo diferencias (p > 0.05) en la estancia hospitalaria. Fue más frecuente la cocleostomía cuando se uso el microscopio. CONCLUSIONES: La endoscopía es un instrumento efectivo en la implantación coclear por timpanotomía posterior, sin presentarse complicaciones y dando mayor seguridad para insertar el electrodo por la ventana redonda.


Assuntos
Implante Coclear , Implantes Cocleares , Criança , Adulto , Adolescente , Humanos , Janela da Cóclea/cirurgia , Endoscopia Gastrointestinal , México
14.
Biomed Microdevices ; 25(4): 41, 2023 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-37870619

RESUMO

Reliability evaluation results of a manufacturable 32-channel cochlear electrode array are reported in this paper. Applying automated laser micro-machining process and a layer-by-layer silicone deposition scheme, authors developed the manufacturing methods of the electrode array for fine patterning and mass production. The developed electrode array has been verified through the requirements specified by the ISO Standard 14708-7. And the insertion trauma of the electrode array has been evaluated based on human temporal bone studies. According to the specified requirements, the electrode array was assessed through elongation & insulation, flexural, and fatigue tests. In addition, Temporal bone study was performed using eight fresh-frozen cadaver temporal bones with the electrode arrays inserted via the round window. Following soaking in saline condition, the impedances between conducting wires of the electrode array were measured over 100 kΩ (the pass/fail criterion). After each required test, it was shown that the electrode array maintained the electrical continuity and insulation condition. The average insertion angle of the electrode array inside the scala tympani was 399.7°. The human temporal bone studies exhibited atraumatic insertion rate of 60.3% (grade 0 or 1). The reliability of the manufacturable electrode array is successfully verified in mechanical, electrical, and histological aspects. Following the completion of a 32-channel cochlear implant system, the performance and stability of the 32-channel electrode array will be evaluated in clinical trials.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Reprodutibilidade dos Testes , Rampa do Tímpano/cirurgia , Janela da Cóclea , Osso Temporal/cirurgia , Cóclea/cirurgia , Eletrodos Implantados
15.
J Assoc Res Otolaryngol ; 24(5): 487-497, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37684421

RESUMO

PURPOSE: Sheep are used as a large-animal model for otology research and can be used to study implantable hearing devices. However, a method for temporal bone extraction in sheep, which enables various experiments, has not been described, and literature on middle ear access is limited. We describe a method for temporal bone extraction and an extended facial recess surgical approach to the middle ear in sheep. METHODS: Ten temporal bones from five Hampshire sheep head cadavers were extracted using an oscillating saw. After craniotomy and removal of the brain, a coronal cut was made at the posterior aspect of the orbit followed by a midsagittal cut of the occipital bone and disarticulation of the atlanto-occipital joint. Temporal bones were surgically prepared with an extended facial recess approach. Micro-CT scans of each temporal bone were obtained, and anatomic dimensions were measured. RESULTS: Temporal bone extraction was successful in 10/10 temporal bones. Extended facial recess approach exposed the malleus, incus, stapes, and round window while preserving the facial nerve, with the following surgical considerations: minimally pneumatized mastoid; tegmen (superior limit of mastoid cavity) is low-lying and sits below temporal artery; chorda tympani sacrificed to optimize middle ear exposure; incus buttress does not obscure view of middle ear. Distance between the superior aspect of external auditory canal and tegmen was 2.7 (SD 0.9) mm. CONCLUSION: We identified anatomic landmarks for temporal bone extraction and describe an extended facial recess approach in sheep that exposes the ossicles and round window. This approach is feasible for studying implantable hearing devices.


Assuntos
Otolaringologia , Osso Temporal , Ovinos , Animais , Osso Temporal/cirurgia , Orelha Média , Processo Mastoide/cirurgia , Janela da Cóclea
16.
J Control Release ; 361: 621-635, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37572963

RESUMO

The semi-permeable round window membrane (RWM) is the gateway to the cochlea. Although the RWM is considered a minimally invasive and clinically accepted route for localised drug delivery to the cochlea, overcoming this barrier is challenging, hindering development of effective therapies for hearing loss. Neurotrophin 3 (NT3) is an emerging treatment option for hearing loss, but its therapeutic effect relies on sustained delivery across the RWM into the cochlea. Silica supraparticles (SPs) are drug delivery carriers capable of providing long-term NT3 delivery, when injected directly into the guinea pig cochlea. However, for clinical translation, a RWM delivery approach is desirable. Here, we aimed to test approaches to improve the longevity and biodistribution of NT3 inside the cochlea after RWM implantation of SPs in guinea pigs and cats. Three approaches were tested (i) coating the SPs to slow drug release (ii) improving the retention of SPs on the RWM using a clinically approved gel formulation and (iii) permeabilising the RWM with hyaluronic acid. A radioactive tracer (iodine 125: 125I) tagged to NT3 (125I NT3) was loaded into the SPs to characterise drug pharmacokinetics in vitro and in vivo. The neurotrophin-loaded SPs were coated using a chitosan and alginate layer-by-layer coating strategy, named as '(Chi/Alg)SPs', to promote long term drug release. The guinea pigs were implanted with 5× 125I NT3 loaded (Chi/Alg) SPs on the RWM, while cats were implanted with 30× (Chi/Alg) SPs. A cohort of animals were also implanted with SPs (controls). We found that the NT3 loaded (Chi/Alg)SPs exhibited a more linear release profile compared to NT3 loaded SPs alone. The 125I NT3 loaded (Chi/Alg)SPs in fibrin sealant had efficient drug loading (~5 µg of NT3 loaded per SP that weights ~50 µg) and elution capacities (~49% over one month) in vitro. Compared to the SPs in fibrin sealant, the (Chi/Alg)SPs in fibrin sealant had a significantly slower 125I NT3 drug release profile over the first 7 days in vitro (~12% for (Chi/Alg) SPs in fibrin sealant vs ~43% for SPs in fibrin sealant). One-month post-implantation of (Chi/Alg) SPs, gamma count measurements revealed an average of 0.3 µg NT3 remained in the guinea pig cochlea, while for the cat, 1.3 µg remained. Histological analysis of cochlear tissue revealed presence of a 125I NT3 signal localised in the basilar membrane of the lower basal turn in some cochleae after 4 weeks in guinea pigs and 8 weeks in cats. Comparatively, and in contrast to the in vitro release data, implantation of the SPs presented better NT3 retention and distribution inside the cochlea in both the guinea pigs and cats. No significant difference in drug entry was observed upon acute treatment of the RWM with hyaluronic acid. Collectively, our findings indicate that SPs and (Chi/Alg)SPs can facilitate drug transfer across the RWM, with detectable levels inside the cat cochlea even after 8 weeks with the intracochlear approach. This is the first study to examine neurotrophin pharmacokinetics in the cochlea for such an extended period of times in these two animal species. Whilst promising, we note that outcomes between animals were variable, and opposing results were found between in vitro and in vivo release studies. These findings have important clinical ramifications, emphasising the need to understand the physical properties and mechanics of this complex barrier in parallel with the development of therapies for hearing loss.


Assuntos
Surdez , Perda Auditiva , Animais , Cobaias , Gatos , Adesivo Tecidual de Fibrina/farmacologia , Ácido Hialurônico , Distribuição Tecidual , Cóclea , Janela da Cóclea/patologia , Janela da Cóclea/cirurgia , Perda Auditiva/terapia , Fatores de Crescimento Neural
17.
Sci Rep ; 13(1): 10967, 2023 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-37414822

RESUMO

The aim of this study was to understand the mastoid volume development in children who undergo cochlear implantation surgery. Cochlear implant (CI) database of our clinic (Kuopio University Hospital) was reviewed for computed tomography (CT) images of CI patients (age under 12 years at the time of implantation) with a minimum time interval of twelve months between their pre- and postoperative CT. Eight patients (nine ears) were found eligible for inclusion. Three linear measurements were taken by using picture archiving and communication systems (PACS) software and the volume of the MACS was measured with Seg 3D software. The mastoid volume increased on average 817.5 mm3 between the pre- and the postoperative imaging time point. The linear distances measured between anatomical points like the round window (RW)- bony ear canal (BEC), the RW-sigmoid sinus (SS), the BEC-SS, and the mastoid tip (MT)-superior semicircular canal (SSC) increased significantly with the age of the patient at both the pre-op and post-op time points. The linear measurements between key anatomical points and mastoid volume showed a positive linear correlation. The correlation between linear measurement and volume were significant between the MT-SSC (r = 0.706, p = 0.002), RW-SS (r = 0.646, p = 0.005) and RW-BEC (r = 0.646, p = 0.005). Based on our findings from the CI implanted patients and comparing it with the previous literature findings from non-CI implanted patients, we could say that the CI surgery seem to have no effect on the development of mastoid volume in children.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Criança , Implante Coclear/métodos , Processo Mastoide/diagnóstico por imagem , Processo Mastoide/cirurgia , Janela da Cóclea/cirurgia , Orelha/cirurgia
18.
Int J Pediatr Otorhinolaryngol ; 171: 111659, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37459768

RESUMO

BACKGROUND: Advancements in imaging and implantation technology have invited reexamination of the classic teaching that the human cochlea maintains uniform size across demographics. Yet, studies yield conflicting results and relatively few broad systematic reviews have examined cochlear size variation. PURPOSE: The purpose of this study is to quantify cochlear variability across eight different measurement categories and suggest normative values and ranges for each with consideration of disease state and gender where possible. METHODS: A systematic search was conducted up to October 1, 2022, using the search terms "Cochlea/anatomy and histology"[Mesh]) AND 'size'" with filters "Humans" and "English" across three databases (PubMed, CINAHL, Medline). Further inclusion criteria involved reporting of numerical measurements in any of the eight included categories. RESULTS: Of the 625 articles manually reviewed for relevance by title and abstract, 91 were selected for full-text review and 33 met all eligibility criteria. 5,791 cochleae were included and weighted means and ranges were calculated: "A" value (defined as the distance from the round window, through the modiolus, to the oppsite lateral wall) = 9.23 mm (8.43-10.4 mm, n = 2559); cochlear duct length (CDL) = 33.04 mm (range 28.2-36.4 mm, n = 2252); cochlear height = 5.14 mm (2.8-6.9 mm, n = 2098); the basal turn lumen diameter = 2.09 mm (1.7-2.2 mm, n = 617); "B" value (defined as perpendicular to "A" value and in the same plane) = 6.52 mm (5.73-6.9 mm, n = 908); width of the basal turn = 6.4 mm (6.22-6.86 mm, n = 356); height of the basal turn = 1.96 mm (1.77-2.56 mm, n = 204); length of the basal turn 21.87 mm (21.03-22.5 mm, n = 384). CONCLUSION: A notable size range exists across the eight different cochlear parameters considered and we provide normative values for each measurement. Females tend to have smaller CDL and "A" value than males and the sensorineural hearing loss patients had smaller CDL and "A" value but larger cochlear height than the general population.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Masculino , Feminino , Humanos , Implante Coclear/métodos , Cóclea/cirurgia , Perda Auditiva Neurossensorial/cirurgia , Janela da Cóclea
19.
Otol Neurotol ; 44(8): e549-e559, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37504977

RESUMO

OBJECTIVE: Active middle ear implants can be directly coupled to the round-window (RW) membrane via RW Vibroplasty. The objectives of this systematic review were to summarize data on different RW coupling techniques and to investigate their effect on audiological and safety outcomes using meta-analyses. DATABASES REVIEWED: PubMed (MEDLINE), Cochrane Library, and Embase (DIMDI). METHODS: All publications reporting on audiological outcomes in human patients after RW Vibroplasty were included. Two independent reviewers carried out screening and data extraction. Meta-analyses and meta-regression were used to evaluate the potential effects of surgical and demographic parameters on primary audiological outcomes. Adverse events were extracted and tabulated for qualitative analysis. RESULTS: Fourteen different combinations of surgical coupling parameters were identified in 61 included publications. Overall, data from 23 publications could be used for meta-analyses. Significantly better aided sound-field thresholds were reported for RW Vibroplasty performed without a dedicated coupler and using fascia as interponate, compared with RW Vibroplasty with an RW coupler or without an interponate. These effects were not found in other outcomes (i.e., functional gain, word recognition score). Reporting of adverse events was relatively heterogeneous, with 32 explicit mentions of revision surgery after the loss of coupling efficacy. CONCLUSION: There are numerous publications investigating the effectiveness of coupling active middle ear implants to the RW membrane. However, studies are typically undersampled and of low evidence level. Using meta-analyses, weighted means, and qualitative analyses enabled a summary of the existing literature on audiological and safety outcomes after RW Vibroplasty. Individual selection of the most appropriate coupling modality with standardized intraoperative measurement and careful patient follow-up may be considered key factors for achieving effective RW coupling.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista , Prótese Ossicular , Humanos , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Resultado do Tratamento , Janela da Cóclea/cirurgia
20.
Wiad Lek ; 76(5 pt 2): 1246-1251, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37364080

RESUMO

OBJECTIVE: The aim: To evaluate the effectiveness of treatment patients with spontaneous PLF and labyrinthine window ruptures by studying the clinical and audiological results. PATIENTS AND METHODS: Materials and methods: 52 patients after exposure to traumatic factors in the anamnesis were evaluated. The perilymphatic fistula was diagnosed in 18 patients after the complex examination. All patients with PLF underwent surgical treatment. RESULTS: Results: Vestibular disorders and hearing loss were the predominant symptoms. The fistula test was positive in 11 (61%) patients. Fluctuating hearing loss was determined in 9 (50%) patients. Labyrinthine window ruptures were detected in 16 (88%) patients: oval window membrane rupture was identified in 6 patients, and in another 10 patients round window membrane rupture was found and was detected on CT scan. The surgical treatment included minimally invasive tympanotomy with combined microscopic and endoscopic visualization and sealing techniques. Results were evaluated in 6 months after surgical treatment, patients had a decrease in bone and air conduction thresholds at all evaluated frequencies and a significant decrease in the level of the air-bone interval. CONCLUSION: Conclusions: Fluctuating hearing loss is considered one of the key symptoms, which suggests the presence of PLF. Determination of PLF and its surgical treatment, by using minimally invasive tympanotomy with sealing technique using optimal combined visualization, allows obtaining a stable functional result, with hearing improvement and vestibular symptoms reducing.


Assuntos
Fístula , Perda Auditiva , Humanos , Resultado do Tratamento , Perda Auditiva/etiologia , Perda Auditiva/cirurgia , Janela da Cóclea/lesões , Janela da Cóclea/cirurgia , Tomografia Computadorizada por Raios X , Fístula/etiologia , Fístula/cirurgia , Fístula/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...